If you have a time-series experiment (e.g., a battery discharging over 10 hours with 20 different EIS files), use the batch fitting feature. Load your optimized model, select , select all 20 files, and ZSimpWin will fit them sequentially, saving hours of manual work. 5. Exporting Your Results Once you are satisfied with the fit: Go to File > Save Results .
| Problem | Solution | |---------|----------| | Program crashes on start | Run as Admin + XP SP3 compatibility | | Plot not showing | Check simulation time limits (e.g., 0–50 sec) | | No dead time effect | Ensure dead time box is checked in process definition | | PID gains not applied | Click Update PID before running simulation | | Text unreadable | Set screen resolution to 800×600 or 1024×768 | zsimpwin tutorial